DBLS-09

產品詳情

Preface

220VAC BL drives is a powerful driver designed by Dingtuo Technology independence which is assorted with the advanced motion control industrial. The drives adopt the latest DSP specialized for motor as the core technical matched with high speed digital logic chips and high quality power module. It gets the advantage on highly integration, small volume, well protection, high reliability etc. This drives can provide: panel speed adjust command, external simulative voltage, external potentiometer, pulse width speed adjust etc.

Product Characteristic

1. System Characteristic:

Input Voltage: AC180/250VAC, 50/60Hz,

Continuous Output current: 8A, suit for less than 1500W brushless motors

Max. Output current: 15A,

Working temp.: 0~+45°C

Storage temp.:-20~+85°C

Working & storage humidity: <85% no frosting

Structure: wall-mountable box type

DimensionL180 x W100 x H210mm

2. Basic Characteristic

Cooling: Radiator

Control terminals Isolation

ProtectionOver load, over heat, over speed, over voltage, lost voltage will cause the power abnormity.

Panel6 digit LED display, 4 digit keypad operation

 

Power Terminal and Motor Terminal

No.

Terminal Name

Signal

Function

1

L1(L)(R)

Power input of main circuit

Main   circuit power input terminal AC220V 50Hz, Connect L1 and L2 while using   single phase voltage 220V

2

L2(N)(S)

3

L3(T)

4

P

High voltage DC bus line terminal

DC bus   line terminal in driver, rated power 315V

5

B1

internal   brake resistance

When using   internal brake resistance, short circuit B1 and B2, when the power is not   enough, need to use external brake resistance, break B1 and B2, connect   external brake resistance with P and B2

6

B2

external   brake resistance

7

U(MA)

Output

The motor   terminals must be connected with U,V,W one-to- one. Attention: do not reverse   the motor by exchange 3 phase terminals, it is completely different with   asynchronous motor

8

V(MB)

9

W(MC)


PE

Protection

The   release way is supplied for protection    motor and drive when current leakage

QQ圖片20170408164544.png   

     

Parameters setup

3.1 Parameters P1

This series characteristics are used to set up some functions by clients self, they can be self-adjust according to clients’ different demand. They are operation functions, have no relation with fundamental characteristics of driver

Function Name

No.

Value Range

Default Value

Function   Specification

Display   optional

P10

0~9

0

0. display real speed

1. display DC voltage of main circuit

2. display external analog input

3. display motor current

4. display internal program speed

5. U phase current

6. V phase current

7. W phase current

8. duty ratio

9 .preserve

Internal running speed

P11

0~9999

2000

When choose internal speed, the data will decide motor’s   speed(view P12)

Choose   signal sourcing  of speed

P1。2

0~2

1

0:internal instruct speed(tP1[0]   is internal speed, when motor running, MUP to up speed ,MDOWN to reduce speed)

1: external terminal analog   input, using SV signal of 7 pin of CN2 as motor’s speed.

2:communication order control

Direction setting

P13

0~1

0

0: CW

1: CCW

Choose   signal sourcing of start-stop

P1。4

0~2

1

0button by   hand controlENT is   start-stop, SET is reverse motor, +/-    is for up and reduce speed

1external   terminal control: using 4pin signal of CN2 to start and stop motor

2: communication order control

pole   pairs of motor

P15

0~99

2

attention:   pole pairs=pole/2

Driver location

P1。6

0~255

0

The driver location when Using communication to control motor

Speed scale factor

P1。7

0~99999

1520

Scale factor using for PID speed control (KP)

Speed integrating factor

P1。8

0~99999

320

Integrating factor using for PID speed control(KI)

Accelerated speed

P1。9

1~60000

6000

The parameters is directly proportional to accelerated speed, the   real accelerated speed is based on loading of motor

Decelerated speed 

P110

1~60000

6000

Rated   speed setting

P1。11

0~99999

3000

Speed corresponding maximum analog input (unit: RPM)

Analog input dead band

P1。12

0~3300

100

The function is used to set input voltage when motor speed is 0   (unit: mV)

Manual operation to adjust   speed equivalent

P1。13

1~999

1

Use bottom to change the speed equivalent under internal speed   type ( speed changed per press)

Recover default parameters

P114

0~1

0

Set up 1 then quit setting, connecting the power again, all   parameters will recover to default value.

3.2 Control panel operation

 QQ圖片20170408164643.jpg

 As picture on left, there are 4 keys on the panel,

 

“SET”: press this key can enter or quite P1 setup menu

 

 “▲”and “▼”: “+”and “-”,to choose the function and adjust the parameters. Otherwise, “+”is the hotkey to enter trial operation function.

 

“ENT”: “confirmation” and “operation”, when setting parameters, press this button to enter adjustment interface and jump. Under trial operation type, press ENT to start or stop motor.

 

Display instruction: total 6 digital tube shows “888888”, the light most is first and the lowest

 

Attention: The adjustment is forbidden if the adjusted value is larger than the maximum allowed, the bottom will be no response.

 

3.3 How to set parameters

 

Example:

Demand: set internal speed (P1.1) to 1000rpm/min

Operation step as below:

 

1. After connecting  with  power, display “H  0”, the driver is standby, press “SET”, will display“P0。 0”
2. Press “SET”, display “P1  0”, the driver is entering P1 setting state
3.Press “▲”, until display “P1
。 4”
4. Press “ENT”, display “2000”, and the first of light most is flashing
5. Press “ENT”, until the flashing is moving to the fourth position
6. Press “▼”, change into “1000”
7. Press “SET”, display “P1
。 4”, the parameters had been set up and save automatic
8. Press “SET” again, display “P2  0”
9. Press “SET” again, back to standby state, display “H  0”, now, the new parameters adjustment had finished and take effect

Attention:
1. after adjustment, the driver need to connect with power again, then the new parameters will take effect   

     2. The parameters with “” in the list can not been adjust when motor working

3. The adjustment is forbidden if the adjusted value is larger than the maximum allowed, the bottom be will no response 

 

Wiring Diagram
QQ圖片20170408164656.png

Functions

1. Speed adjustment method

This driver provide below three adjust methods for the user to choose: 

Analog voltage adjustment speed: the terminals of external potentiometer connect to the +5v terminal in signal control and COM, connect the regulator terminal to SV, not only make it possible to adjust speed by external potentiometer (10K~100K), but also can achieve speed adjust through other control unit (Such as PLC, Microcontroller, etc) input analog voltage to SV. The acceptance of SV is DC 0V~+5V, and the corresponding motor rotate speed is 0 to rated speed.

You also can use external digital signal to adjust speed: apply PWM with 5V amplitude and 1KHz~2KHz Frequency between SV and GND to adjust the speed. The motor rotate speed will adjust by the duty radio liner adjustment.

The third method to adjust speed is using communication order controlling

2. Motor operate/stop control (EN)
You can control the brushless motor to run or stop by controlling the terminal “EN” and “COM” connecting. The motor will run when we connect the terminal “EN” to “COM”; when shut down, the motor will stop naturally. And the starting time will decided by the initial setup in panel, the motor running will be affected by load added 

3. Motor rotation direction control ( F/R )
You can control the motor rotation direction by controlling the terminal “F/R” and “COM” connecting. When connect terminal “F/R” to terminal “COM”, the motor will run at CCW (view from motor output side), and when shut down, the motor will run at another direction.

Attention: If you need to change the motor rotation direction, please stop the motor at first, otherwise the controller shall be caused to damage.

4. Break the motor to stop  ( BK )
You can break the motor to stop if need. Motor can be running when the terminal “BK” not connect to “COM”, but if you connect these two terminal together, motor will stop quickly. If the overload alarm frequently, you need to add brake resistance for driver, the resistance value is not less than 100Ω, and power is not less than 100W. Attention: when install the brake resistance, the driver must be under without power and indicating light state. The brake resistance accessories is for charge

5. Speed signal output (PG) 

The speed pulse output is 0C, output 30V/10mA max. You can connect with a resistance (3K ohm ~10K ohm) between PG and the input power to get the speed pulse signal. The relationship of output frequency F(Hz) and speed N(rpm)is: F=N * P / 60 , P is the pole pairs of motor, Output Pulse per revolution.

6. Alarm output (ALM)
The alarm output port is 0C, output 30V/10mA max. You can connect with a resistance (3K ohm ~10K ohm) between ALARM output and the input power to get the alarm signal. When alarm, this port and the GND connecting (Low voltage), and the controller will stop working and keep in alarm status.

Working methods

The driver has three working methods by setting panel. The first is panel manual operation, press R/S to start or stop the motor, press + - to up or reduce the speed, press∣”ENTER to confirm the speed. The second is by external terminals, the motor is working with settle, digital tube display running speed. The third method is communication type.

Protection type

When the motor is running abnormally, the digital tube will display:

(1) OL   motor locked。

(2) OC   over current。

(3) HE   hall signal failure

(4) LV   under voltage input 。

(5) HU   over voltage input。

(6) EE   IPM failure protection。

(7) OT   motor too hot

 

System using

Firstly, connect motor and driver lines (wounding lines, hall signal lines and power line) in strictly observe related norms and specification. It can’t to reverse the motor by change lines connection, it is completely different with asynchronous motor. The motor and driver can not work normally even damaged if lines connected wrong

You can start the trial operation after connecting motor power line, hall line and driver power lines. At first, set the control panel or terminal control, secondly set the pole pairs of brushless DC motor (wrong pole pairs will display inaccurate speed and offer wrong inner parameter ), then press the start button, enlarge the potentiometer slightly , the motor will run, if the motor do not work, or shake, or alarm, maybe the lines connection is not correct, or load is too large, please check again, until the motor running normally.

 

上一個:
下一個:
?

2006-2024 深圳市鼎拓達機電有限公司版權所有 粵ICP備05142847號 技術支持:神州通達網絡

深圳總公司:

電話:0755-25796858 

傳真:0755-25796696 

郵箱:sales@dt-me.com 

地址:廣東省深圳市南山區(qū)西麗街道麻磡社區(qū)麻磡路18號工業(yè)區(qū)8棟5樓




華中辦事處:童仁青  18975332020 

地址:湖南省長沙縣星沙大道39號財富港灣1棟2單元1613號

華東辦事處:朱興科 18128820282  

地址:江蘇省蘇州市昆山市昆山開發(fā)區(qū)四季華城32棟2單元1503

 
微信掃一掃   手機掃一掃
在線客服
欧美成人精品第一区二区三区| 久久亚洲美女精品国产精品| 曰韩无码AV一区二区免费| 久久亚洲av成人无码| 韩国三级中文字幕HD久久精品| 日韩精品国产另类专区| 五十老熟妇乱子伦免费观看| 91黄色视频在线观看| 成人免费看片又大又黄| 亚洲精品第一国产综合亚av| 国产精品久久久久无码av| 国产免费观看久久黄av片| 精品国产AV色欲果冻传媒| 欧美精品久久久久久久免费观看| 国产综合色在线视频区| 国产亚洲欧美日韩俺去了| 蜜臀av无码人妻精品| 亚洲欧美中文日韩在线V日本| 自拍偷自拍亚洲精品被多人伦好爽| 成人在线精品| 激情综合婷婷丁香五月俺来也| 粉嫩大学生无套内射无码卡视频| 日韩一区二区三区精品| 亚洲免费成人| 亚洲熟女综合色一区二区三区| 国产精品国产三级在线专区| 免费无码av一区二区| 国产成人综合久久精品推最新| 中国国语毛片免费观看视频| 337p日本欧洲亚洲大胆人人| 欧美成人尤物影院视频在线播放| 国产精品毛片久久久久久久无码| 亚洲最大AV资源网在线观看| 亚洲精品无码人妻无码| 香蕉久久精品日日躁夜夜躁夏| 色欲av无码一区二区三区| 欧美人牲交免费观看| 99色在线视频| 亚洲AV永久无码天堂网毛片| 老师穿着旗袍肉色丝袜让我玩| 少妇AAA级久久久无码精品片|